sensing distance: 22 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NO (short circuit when door is open)
sensing distance: 22 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NO (short circuit when door is open)
micro switch | sensing distance: 3 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
sensing distance: 25 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 78 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 55 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 55 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 50 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
ABS plastic | 3 contacts | 2 A @ 36 V DC | flush mountable into hinge side
ABS plastic | 2 contacts | 5 A @ 36 V DC | flush-mountable into lock side
ABS plastic | 2 contacts | 5 A @ 36 V DC | flush-mountable into lock side
ABS plastic | 3 contacts | 3 A @ 36 V DC | flush mountable into hinge side
ABS plastic | 5 contacts | 3 A @ 36 V DC | flush mountable into hinge side
ABS plastic | 2 contacts | 2 A @ 30 V DC | flush mountable into hinge side
ABS plastic | 2 contacts | 2 A @ 30 V DC | flush mountable into hinge side | black
sensing distance: 16 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NO/NC
mini | sensing distance: 15 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
mini | sensing distance: 15 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
Nominal voltage: 275 V AC|Network type: TN-S, TN-C-S, IT|Nominal current: 10 kA|Connectable wire: 4 - 25 mm2
Impulse | 2 channel | Relay load capacity: 10 A@250 V AC | Output voltage: 12 V AC | Wiring: soldered | NO/NC
Function: Cable clamp | Mounting: Surface mounting with double-sided adhesive
2 channel | Power supply: 12/24 V DC | Output max. load: 10/6 A@125 V AC/24 V DC | NO/NC
Function: Lock control | Fail-safe (NC) locks | Wiring: terminal block | Dimensons: 69×60×15 mm
Timing: 0-30s | Output: NO/NC | Power supply: 12 V DC | Output max. load: 10A @ 12 V DC
1 channel | Power supply: 12 V DC | Output max. load: 10 A@120 V AC | Wiring: terminal block | NO/NC
1 channel | Power supply: 12/24 V DC | Output max. load: 10/6 A@125 V AC/24 V DC | NO/NC
1 channel |Power supply: 12/24 V DC | Output max. load: 7A @230V | NO/NC
2 channels | Power supply: 12 V DC | Output max load: 1A@125V AC, 2A@30V DC | NO/NC
Function: Timing and Delay | Relay: Yes | Display: 7-segment | Timing and Delay Range: 0.1 seconds - 999 minutes | Modes: 9 different modes
Function: timing and delay | Relay: Yes | Display: 7-segment | Timing and delay range: 0,01 seconds - 999 minutes | Programs: 32
sensing distance: 14 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 14 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 14 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 19 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NO/NC
sensing distance: 16 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 16 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 12 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 12 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)
sensing distance: 18 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
sensing distance: 18 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
sensing distance: 15 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
sensing distance: 15 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
sensing distance: 15 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
sensing distance: 18 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
sensing distance: 29 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
sensing distance: 29 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | flush mount | NC (short circuit when door is closed)
sensing distance:50 mm | current rating: 0,1 A @ 12 V DC (0,12 W) | surface mount | NC (short circuit when door is closed)